Client:
AFISA
Location:
Douala Port, Douala - Cameroon

Foundation Piles Dia. 880/780

Nos. of Piles:
529
Total Drilling Length:
13300m
Max. Pile Length:
31m

Shoring Piles Dia. 880/780

Nos. of Primary Piles:
26
Nos. of Secondary Piles:
26
Total Drilling Length:
780m
Max. Pile Length:
15m
Exposed Shoring Depth:
5.5m

The project consists of the construction of a new wheat bulk unloder building and 8 storage silos. PFS was awarded the contract for execution of 529 foundation piles and 52 shoring piles based on secant pile wall system. Due to the subsurface conditions, PFS had to drill the piles in unknown soil conditions, including old reinforced concrete slabs with steel reinforcement rebars reaching 40mm diameter. In addition to the foundation piles, and since a pit of approx. 5m must be done under the building, including 3.5m under the groundwater table, PFS has proposed to install a secant pile wall system before the excavation of the pit in order to ensure the required dry conditions for construction works.